Insert central spout appears on the coffee machine display even though the central spout is inserted (countertop coffee machine).

The magnet is missing from the suction nozzle of the central spout.

Suction nozzle magnet | Central spout | Countertop coffee machines

A small magnet has been fitted in the suction nozzle of the central spout, see figure. The magnet might drop out by accident when the central spout is being cleaned.

Check the serial number and the index number on your coffee machine’s data plate. Magnets have not been fitted to coffee machines from no. 13 / 097367459 onwards.

Position of data plate | Countertop coffee machines

The data plate for your coffee machine is located behind the drip tray.

Switch the coffee machine off.

Pull the stainless steel cover off the central spout.

Pull the dispensing unit forwards and off.

Check for a magnet inside the suction nozzle, see figure.

If a magnet has been fitted, reposition it correctly inside the suction nozzle.

Refit the dispensing unit in the central spout.

Refit the stainless steel cover.

Switch the coffee machine on again.

If the fault persists, please contact Miele Customer Service or book a repair appointment online.